Key Conclusion: What Is ALPHA2 15-60 130
Product Positioning and Construction
High-efficiency canned-rotor circulator for circulating liquids in heating systems. Pump and motor form an integral unit; bearings are lubricated by the pumped liquid ensuring maintenance-free operation, with dry-running protection. Ceramic shaft and radial bearings, carbon thrust bearing, stainless-steel rotor can, bearing plate and rotor cladding, and a composite impeller. The pump is self-venting through the system; the compact pump head has an integrated control box and operating panel. The cast-iron pump housing (EN 1561 EN-GJL-150 / ASTM A48M-150B) is electrocoated to improve corrosion resistance. The motor is a synchronous permanent-magnet/compact-stator motor; pump speed is controlled by an integrated frequency converter in the control box.
AUTOADAPT and control modes
The AUTOADAPT function continuously adjusts pump performance to the actual heat demand (the size of the system and the changing heat demand during the year), finding the setting that provides optimal comfort with minimal energy consumption. In addition, the pump features three control modes, each with three settings: proportional-pressure control, constant-pressure control and constant-curve control. The display shows actual power consumption in watts or actual flow in m3/h as well as alarms and warnings; LEDs indicate the operating status. The night-setback function reduces motor speed to save energy, with changeover depending on the flow-pipe temperature. Once manual summer mode is enabled, the pump starts frequently at low speed to avoid blocking the rotor.
Installation and Connections
Pump head orientation 6H; connection type G, size 1 inch, pressure rating PN 10, port-to-port length 130 mm; ambient temperature range 0 .. 40 °C, maximum operating pressure 10 bar, liquid temperature range 2 .. 110 °C, pumped liquid water (20 °C, density 998.2 kg/m³).
Key Specifications (Product No. 98485645)
| Item | ALPHA2 15-60 130 |
|---|---|
| Product name | ALPHA2 15-60 130 |
| Product No. | 98485645 |
| EAN number | 5711495938482 |
| Rated flow | 1.94 m³/h |
| Rated head | 3.28 m |
| Maximum head | 60 dm |
| Pump head orientation | 6H |
| TF class | 110 |
| Approvals | CE, VDE, CH ROHS |
| Model | D |
| Pump housing | Cast iron (EN 1561 EN-GJL-150 / ASTM A48M-150B) |
| Impeller | Composite (PES 30% GF + PESU-GF20%) |
| Range of ambient temperature | 0 .. 40 °C |
| Maximum operating pressure | 10 bar |
| Type of connection | G |
| Size of connection | 1 inch |
| Pressure rating for connection | PN 10 |
| Port-to-port length | 130 mm |
| Pumped liquid | Water |
| Liquid temperature range | 2 .. 110 °C |
| Selected liquid temperature | 20 °C |
| Density | 998.2 kg/m³ |
| Minimum power input - P1 | 3 W |
| Power input P1 | 34 W |
| Mains frequency | 50 / 60 Hz |
| Rated voltage | 1 x 230 V |
| Maximum current consumption | 0.04 .. 0.32 A |
| Enclosure class (IEC 34-5) | IPX4D |
| Insulation class (IEC 85) | F |
| Thermal protection | ELEC |
| Aut. night | automatic reduced night-time duty included |
| Energy (EEI) | 0.17 |
| Net weight / Gross weight | 1.73 kg / 1.88 kg |
| Shipping volume | 0.004 m³ |
| Custom tariff no. | 84137099.90 |
| Sales region | CN |
Note: Only items explicitly given in the official datasheet are listed; items not stated are marked as such, with no values fabricated or inferred.
AUTOADAPT and control features (from the product description)
The points below are reproduced from the product description in the official datasheet for this product number:
• The AUTOADAPT function automatically finds the best setpoint and thus reduces the energy consumption and setup time • Pumps are supplied with insulating shells to minimise energy heat loss in heating and cooling systems • A display shows the actual power consumption in watts or actual flow rate in m3/h for control purposes • The best energy efficiency index (EEI) in the market provides the highest energy savings over a year • Stainless-steel pump housings are available if the application requires corrosion resistance or for drinking water, DHW applications • Complies with the German regulation for energy saving in buildings and building systems, Energieinsparverordnung-EnEV §14(3) • Automatic night-setback function that further reduces the energy consumption if the boiler provides this feature • Simple selection among three constant-pressure curves, three proportional-pressure curves or three fixed speeds with only one button • ALPHA plug. Easy, quick and safe electrical connection; ALPHA2 is suitable for cold-water systems with drinking water approval • Electrocoated pump housing; no external motor protection is required • New improved start. Secure start under tough conditions; new advanced dry-running protection • Manual summer mode. Saves energy during the summertime with a consumption <0.8 watt and ensures safe start at the next heating season