Key Conclusion: What Is COMFORT 15-14 B TDT
Product Positioning and Control Logic
COMFORT TDT is an efficient circulator designed for hot-water recirculation in residential buildings with a dedicated return line. It is compatible with all types of water heater tanks, tankless systems, solar or heat pumps, whether or not the system has mixing or tampering valves installed. The pump features a compact housing and a permanent magnet with an integrated control unit. The spherical rotor, equipped with an impeller, is supported by a robust single-bearing ball system. The drinking-water-approved brass pump housing guarantees safety and reliability, and a built-in temperature sensor maintains precise water temperature. The user-friendly interface features LEDs and pushbuttons for displaying and setting operating times and control modes.
Timer Control Mode
The pump operates continuously based on set operating times, with the smallest time increment being 30 minutes. In case of power failure, the timer pauses (no power reserve), but the selected operating times and current time are retained. When power is restored, the pump resumes its last set operating state. If the power outage exceeds 15 minutes, the current time may need to be reset.
Timer and Temperature Control Mode (Time Priority)
The pump operates based on set operating times and the functionalities of temperature mode, with operating times taking priority — the temperature mode is only active during the specified operating times. This mode automatically activates the pump when the internal temperature sensor detects that the water temperature drops below a certain level. On/off temperatures are automatically adjusted based on the maximum temperature measured in the system; the maximum temperature is measured every 12 hours for 15 minutes, enabling dynamic adjustment of the on/off temperatures.
Variant and Optional Accessories
The BX variant includes non-return and shut-off valves, reducing installation cost. Optional: a venting flange (simple venting/draining without an additional permanent venting valve), fittings for pipe connections of different sizes and types, and non-return and shut-off valves.
Key Specifications (Product No. 93094769)
| Item | COMFORT 15-14 B TDT |
|---|---|
| Product name | COMFORT 15-14 B TDT |
| Product No. | 93094769 |
| EAN number | 5715467694895 |
| Speed no. | 1 |
| Rated flow | 0.45 m³/h |
| Rated head | 0.9 m |
| Maximum head | 14 dm |
| TF class | 95 |
| Approvals | VDE, CN_ROHS |
| Pump housing | Brass (CuZn39Pb3, MS58) |
| Impeller | Composite (PPO-GF20 / Stainless steel) |
| Minimum ambient temperature | 0 °C |
| Maximum operating pressure | 10 bar |
| Pipe connection standard | ISO 228-1 |
| Type of connection | Rp |
| Size of connection | 1/2 inch |
| Pressure rating for connection | PN 10 |
| Port-to-port length | 80 mm |
| Pumped liquid | Water |
| Liquid temperature range | 2 .. 95 °C |
| Selected liquid temperature | 20 °C |
| Density | 998.2 kg/m³ |
| Max. power input | 7 W |
| Mains frequency | 50/60 Hz |
| Rated voltage | 1 x 230 V |
| Current in speed 3 | 0.07 A |
| Enclosure class (IEC 34-5) | IP44 |
| Insulation class (IEC 85) | F |
| Built-in motor protection | ELECT. |
| Thermal protection | Impedance protected |
| Operation mode included (datasheet table) | Timer (timer + temperature per description text) |
| Net weight / Gross weight | 0.94 kg / 1.04 kg |
| Shipping volume | 0.003 m³ |
| Sales region | China |
| Country of origin | DK |
| Custom tariff no. | 84137099.90 |
Note: Only items explicitly given in the official datasheet are listed. The datasheet table lists "Timer" under operation modes; the timer-and-temperature logic is described in the description text and presented accordingly. No values have been fabricated or inferred.
Key Features and Benefits
① Time and temperature control, 56% heat loss reduction
Timer mode operates on set times (smallest increment 30 minutes); timer+temperature mode starts on temperature within the set operating window. Compared to continuously running pumps, heat loss is reduced by 56%, with low power consumption and silent operation.
② Drinking-water-approved brass housing
Approved for drinking water: brass pump housing (CuZn39Pb3, MS58), stainless-steel rotor and composite impeller (PPO-GF20). Removing the pump head makes it easy to remove limescale and foreign deposits, meeting unlimited water hardness requirements.
③ Dry-running protection and multiple installation positions
Dry-running protection prevents failure if the system runs out of water. Multiple installation positions are supported, even with the pump head pointing downwards. The pump head fits brass housings of old and new pumps of the same design, including different manufacturers (Wilo, Vortex, Lowara, DAB, etc.).
④ Easy electrical installation and insulation
A pre-assembled power plug with a 1.5 m cable and double insulation protection eliminates the need for a ground wire. Insulating shells reduce heat loss, and the pump complies with pipe manufacturers' flow velocity limits (DN 15, DN 20 PEX, copper, etc.).
Applications and Selection Tips
- Residential hot-water recirculation: For residential buildings with a dedicated return line, single- and multi-family homes; Q-H performance is designed around duty points compensating for heat loss in a specific pipe layout.
- Multiple heat sources: Compatible with all types of water heater tanks, tankless systems, solar or heat pumps, with or without mixing or tampering valves.
- Selection tips: Check against rated flow 0.45 m³/h, rated head 0.9 m, maximum head 14 dm; confirm power supply 1 x 230 V / 50-60 Hz and connection Rp 1/2 inch (port-to-port 80 mm, PN 10); liquid temperature range 2 .. 95 °C and maximum operating pressure 10 bar.