Overview: What is the Wilo PEXO series
Model selection table (Model · Article number · Connection · PN)
| Model | Article number | Pump connection | Max. operating pressure PN |
|---|---|---|---|
| PEXO 4-16 | 9277756 | G 1 | 5 bar |
| PEXO 5-22 | 9277757 | G 1 | 5 bar |
| PEXO 6-26 | 9282396 | G 1 | 5 bar |
| PEXO 7-30 | 9277758 | G 1 | 5 bar |
| PEXO 12-7 | 9277759 | G 1¼ | 5 bar |
| PEXO 14-12 | 9277760 | G 1¼ | 5 bar |
| PEXO 16-16 | 9277761 | G 1½ | 5 bar |
| PEXO 18-24 | 9277762 | G 1½ | 5 bar |
| PEXO 22-30 | 9277763 | DN 40 | 5 bar |
All 9 models share the same maximum operating pressure of PN 5 bar. Connection sizes step up from G 1 (smaller types) to G 1¼, G 1½ and DN 40 (larger types) as flow capacity increases.
Series technical data (from the datasheet's general technical section)
- Fluid temperature: not below 0 °C and not above +90 °C (the individual data sheets of PEXO 4-16 … 16-16 state 5…95 °C; PEXO 18-24 and 22-30 state 0…90 °C – see the detailed table below).
- Fluid pH value: 6.5 – 8.5.
- Solids content: max. 0.1 % by volume; particle size max. 0.2 mm.
- Ambient temperature: 0 °C to 40 °C.
- Installation altitude: below 1000 m.
- Relative humidity: below 90 %.
Note on fluid-temperature ranges
The datasheet's general "Technical data" section specifies a fluid temperature of 0… +90 °C. The individual type data sheets, however, list slightly different limits: PEXO 4-16, 5-22, 6-26, 7-30, 12-7, 14-12 and 16-16 are specified with 5…95 °C, whereas the larger PEXO 18-24 and 22-30 are specified with 0…90 °C. Both figures are reproduced verbatim from the datasheet; for a given project, apply the limit stated for that specific type.
Detailed parameters – all 9 models
| Model | Article no. | P₂ | Rated current | Rated speed |
Insul. class | Prot. class | Motor protection | Eff. class |
Housing | Impeller | Net weight | Fluid temp. | Conn. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PEXO 4-16 | 9277756 | 0.2 kW (200 W) | 1.06 | 2850 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 9.5 | 5…95 °C | G 1 |
| PEXO 5-22 | 9277757 | 0.3 kW (300 W) | 2.04 | 2835 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 10.5 | 5…95 °C | G 1 |
| PEXO 6-26 | 9282396 | 0.45 kW (450 W) | 2.85 | 2850 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 10.5 | 5…95 °C | G 1 |
| PEXO 7-30 | 9277758 | 0.6 kW (600 W) | 3.84 | 2805 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 9 | 5…95 °C | G 1 |
| PEXO 12-7 | 9277759 | 0.2 kW (200 W) | 1.06 | 2850 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 11 | 5…95 °C | G 1¼ |
| PEXO 14-12 | 9277760 | 0.35 kW (350 W) | 2.36 | 2830 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 12.5 | 5…95 °C | G 1¼ |
| PEXO 16-16 | 9277761 | 0.6 kW (600 W) | 3.84 | 2805 | F | IP44 | PTO | GB3 | Grey cast iron | PPO / PS-GF30 | 14 | 5…95 °C | G 1½ |
| PEXO 18-24 | 9277762 | 1.2 kW (1200 W) | 2.61 | 2855 | F | IP55 | No (none) | IE3 | Grey cast iron | PPO / PS-GF30 | 18 | 0…90 °C | G 1½ |
| PEXO 22-30 | 9277763 | 1.8 kW (1800 W) | 3.78 | 2860 | F | IP55 | No (none) | IE3 | Grey cast iron | PPO / PS-GF30 | 20.5 | 0…90 °C | DN 40 |
Rated current in A; rated speed in 1/min; net weight in kg; fluid temperature as specified per type. Efficiency class: GB3 for PEXO 4-16 … 16-16, IE3 for PEXO 18-24 and 22-30 (per the datasheet tender text). Motor protection: PTO (automatic motor protection) for PEXO 4-16 … 16-16; no motor protection for PEXO 18-24 and 22-30.
Materials & motor protection
- Pump housing: Grey cast iron (all 9 models).
- Impeller: PPO / PS-GF30 (all 9 models).
- Motor protection: PEXO 4-16, 5-22, 6-26, 7-30, 12-7, 14-12 and 16-16 are equipped with PTO – the stator winding over-temperature protection that automatically stops the pump and restarts it after cooling. PEXO 18-24 and 22-30 have no built-in motor protection.
- Protection class: IP44 for PEXO 4-16 … 16-16; IP55 for PEXO 18-24 and 22-30.
- Insulation class: F for all 9 models.
Material note (no stainless version in this datasheet)
This Wilo PEXO datasheet specifies a grey cast iron housing and a PPO / PS-GF30 impeller for every listed type. It does not list a stainless-steel (e.g. 316) variant of these PEXO models; do not assume one exists from this document.
Applications
- Domestic & building water boosting: pressure increase for cold and hot potable-water systems within the stated temperature and PN 5 bar limits.
- Hot & cold water transfer: circulation and transfer of clean water in residential and light commercial buildings.
- General clean-water duties: where a compact, low-noise booster is required and the fluid stays within pH 6.5–8.5, solids ≤ 0.1 % (≤ 0.2 mm), ambient 0…40 °C.
FAQ
Source
Data source
All parameters on this page are taken verbatim from the Wilo official product datasheet wilo-datasheet_cn_en_pexo_id9828.pdf (article numbers 9277756–9277763; sales availability 2026-01-05). Fields the datasheet does not state (EAN, number of stages, head/flow duty values, gross weight, supply voltage, MEI, shaft-seal type and drinking-water certifications) are not listed here and are not estimated.